• I want to thank all the members that have upgraded your accounts. I truly appreciate your support of the site monetarily. Supporting the site keeps this site up and running as a lot of work daily goes on behind the scenes. Click to Support Signs101 ...

Recent content by odshawaii

  1. Suggestions JV33 - Magenta starvation but comes back after hard clean

    Aloha Edgar, See attached pics: I opened the cover in the back to inspect the valves and ink lines. The lines are filled with ink and the brass nuts seem to be torqued securely to the lines. I did not attempt to undo any parts as I didn't want to risk making my problems any worse...
  2. Suggestions JV33 - Magenta starvation but comes back after hard clean

    Thank you for the tips Edgar. Any pictures you can send would be of great help. Here in Hawaii, we don't have Mimaki technician so these technical troubleshoots can be a bit hairy for me.
  3. Suggestions JV33 - Magenta starvation but comes back after hard clean

    So I tried the steps you shown me. I pulled ink from both lines gently and ink were drawn out on both (vacuum on both lines). It wasn't just air like how it was shown on your video. I am not too sure if I performed it correctly but the problem is still there. Just a reminder that the cap top...
  4. Suggestions JV33 - Magenta starvation but comes back after hard clean

    Thank you for the steps and video. I will give this a try soon and update this post.
  5. Suggestions JV33 - Magenta starvation but comes back after hard clean

    Yes, I've done the cap adjustments based the best I could. Any chance you can share a video or step-by-step photos of that syringe test you are referring to?
  6. Suggestions JV33 - Magenta starvation but comes back after hard clean

    Just installed a new oem cap top and the exact problem still persists. The pump, cap top and dampers have all been replaced just a few months ago. However, the printhead is a few years old. Hopefully someone here can help shed some light on this. The brightside to this is that I am still...
  7. Suggestions JV33 - Magenta starvation but comes back after hard clean

    Thanks, I'll give it a try and replace the cap with a brand new one.
  8. Suggestions JV33 - Magenta starvation but comes back after hard clean

    Yes, it came with a 3rd port hole with a blue stopper that's still on there.
  9. Suggestions JV33 - Magenta starvation but comes back after hard clean

    This is what my cap top looks like after a hard clean (see pic): Any suggestions?
  10. Magenta dropping out of JV33

    Do you have a picture to show exactly what you cleaned and retightened?
  11. Suggestions JV33 - Magenta starvation but comes back after hard clean

    Thanks Alan - I checked the hoses between the captop and the pump and they didn't seem to be super snug (made adjustments to them). If that doesn't work, I'll replace the cap top again with a new oem one. I can't recall if I used a 3rd party cap the last time.
  12. Suggestions JV33 - Magenta starvation but comes back after hard clean

    The damper and cap top were recently replaced a few months ago. The pump is about 6 months old too.
  13. Suggestions JV33 - Magenta starvation but comes back after hard clean

    Hello, Not sure if anyone here has experienced this issue... I have one magenta (far right) that seems to be starving everyday practically, but everytime I do a hard clean, the magenta comes back to life. I was considering popping off the damper and try to inject cleaning solution into the...