I am using Flexi 22 to create an ICC profile with the X-Rite Eye-one. When I Rip the colors print out completly wrong...
Anybody has some advice on how to troubleshoot?
I have seen several posts about this. Need some advice if you have a Epson SC.
Epson seems to beat the Roland, but what about the TrueVis?
Is the print quality so much better than the roland, and machine durability? we have a VP540i and is still working after 15 years...
Also what is the...
Tried pulling down to make sure I'm getting new ink and sill having the same problem.
Is there are color setting hard coded in the machine that may need resetting?
Tried with the other cartridges and the same problem. is there a config setting in the machine? we have tried with two different computers and they both print the same magenta tone.
No we havent changed anything, we are using a CISS system, they come with a chip. I have some compatible cartridges that I will try to see if its a chip problem.
I have a problem with the color tonality. The nozzle check seems ok, bit I am getting all prints more magenta than normal. This has happend suddenly ... no changes have been made.
Anybody has had this?
not yet. Will try that. Thanks.
On another note , I am getting 1.8v on my earth (using multimeter connecting neutral + earth). Is this normal or could there be an electrical problem?
If anybody has a problem with these chinese printers. The problem I had was the printhead height .. It has to be a perfect height for the ink vacuum to occur.
Hello, I have a problem with my chinese printer Galaxy UD251LA. The printer has been working fine for several years. I think the last time I changed the printhead was 3 years ago.
I get this red spray... but the head seems to print ok and the test print looks good.
Would this be a problem...
yes I know, this is always last resort before buying a new head.
Could it be the head height? I have also changed the datacables and print head fuses.
Anybody has some information on how to calibrate the head height.
thanks
here is the print test. I have also changed the manifold by the way, could this be a calibration error?
I have also done a manual head cleaning, with very little preassure not to brake anything inside... I could see the spray deviated.
I will post a print test shortly.. here is another picture... its looks like there is serious deviation. Is there any solution I could try, or is the head gone?!
Hi have a problem with magenta on the roland VP540i, I am getting this blur or overspray .. I have changed the data cableswith new ones but still the same issue...
has anybody had this problem?
thanks
another problem now with new printhead!!!! must be electrical or static!!!!
yes, have changed the cables with another printer..
* to note we have changed to a new location 3-4 months ago, previously everything has been fine.
yesterday black started failing.. printed a test and this is what I...