• I want to thank all the members that have upgraded your accounts. I truly appreciate your support of the site monetarily. Supporting the site keeps this site up and running as a lot of work daily goes on behind the scenes. Click to Support Signs101 ...

Search results

  1. UJF 6042 - Test Prints after Head Replacement

    Here's the TL;DR on the situation: Bad ribbon cables/connection on printhead. I had tried cleanings between each of the test prints, but got the same results. I didn't attempt to run an actual print, just test prints. I removed the cables and re-seated them 4 times, but still got the same...
  2. UJF 6042 - Test Prints after Head Replacement

    Hi All, I replaced a print head on on of my Mimaki UJF-6042 printers today. The print head that was removed had significant clogs in the nozzles, and was affecting the colors of my prints. The nozzle recover function was enough to get me by for awhile, until today. Anyways, I replaced the...
  3. Mimaki UJF-6042 - Error Code: 12a Head Faild [0010]

    Update : Mimaki UJF-6042 - Error Code: 12a Head Faild [0010] So it's been a few months since I've been actively on the boards, and I have an update to the issue that we experienced with our UJF-6042... After much trial, error, and disassembly we found out the the printer had a faulty PCB...
  4. Mimaki UJF-6042 - Error Code: 12a Head Faild [0010]

    Hello All, We've received the following error code on one of our Mimaki UJF-6042 printers: ERROR 12a Head Faild [0010] I've contacted our dealer tech and ran through his recommended steps to try and resolve the error: - Turn off power to machine (front panel button, and switch on back of...
  5. Mimaki 6042 - Special Color printing in wrong position

    I've run in to a significant issue when printing with one of our Mimaki UJF-6042: Our "special color" is being offset from the primer and color layers that are being printed (example of print below, with abnormal prints highlighted in yellow ellipse). The white layer is offset by roughly 0.02...
Top