• I want to thank all the members that have upgraded your accounts. I truly appreciate your support of the site monetarily. Supporting the site keeps this site up and running as a lot of work daily goes on behind the scenes. Click to Support Signs101 ...

Search results

  1. Variable Data - Is this possible?

    This reply is a too late for this member but might help others in the future. I am a director with Pyxis software who develop both custom and off the shelf applications for the print and packaging sectors. One of our applications, PYXIS IMPOSED, would probably do this job in a much simpler way...
  2. VJ-1604 SubTankLo Error

    Thanks for this info. And the printer has continued to work with with the old valve. Henryp, I will keep these connector issues in mind. To check if it was the wiring or the valve was at fault, I turned off the machine and switched the wires going to the valves on subtanks 1 and 4. I then...
  3. VJ-1604 SubTankLo Error

    For those interested, the Mutoh did print with the valve removed, but there appeared to be lot of yellow going into the waste container. It was also dribbling a bit, mostly outside of the print area. Anyway, I used some alcohol to clean the valve. I used a plastic coated paperclip to work the...
  4. VJ-1604 SubTankLo Error

    A short update on the Mutoh SubTankLo error. There is a link at the top of this post to a thread that shows how to "exercise the valves". I went back to this again and noticed that will all valves were set to on, that when I checked each one, turning it on and off, I could hear a clear clicking...
  5. VJ-1604 SubTankLo Error

    Following your advice, Jiarby, I used the syringe but because the line is forked and there are two yellow dampers, I have been able to pull the ink to the head just above the dampers. Is this enough? or do I need fill the last 8 to 10cm of pipe. Will that remaining air in the system cause...
  6. VJ-1604 SubTankLo Error

    Thanks, Jiarby. I'll give that a try and let you know if this works.
  7. VJ-1604 SubTankLo Error

    Yes Compilla, this thread was relevant. I checked the Hidden Menu, as shown by MacDaddy and all of the valves were on. I investigated further and removed the pipe from the yellow sub tank at the print head (when the machine was powered off) and the ink disappeared back along the tube (I guess...
  8. VJ-1604 SubTankLo Error

    Many thanks for this. I will check out this link and let you know if it helps.
  9. VJ-1604 SubTankLo Error

    I have a ValueJet 1604 which is about 13 months from new. An error message has been appearing occasionally, but now more than before: E122 Err SubTankLo Y. Any help would be much appreciated. Thanks in advance. I've only stumbled upon this forum recently and think it is an excellent resource.
Top