• I want to thank all the members that have upgraded your accounts. I truly appreciate your support of the site monetarily. Supporting the site keeps this site up and running as a lot of work daily goes on behind the scenes. Click to Support Signs101 ...

Recent content by Tshof

  1. Need Help UJF-6042 MkII Head Temp. Control

    We just b We just bypass ours. Have been for 5 years. Still running strong. Even our tech knows we do. Never a problem unless we forget to punch the button l
  2. Need Help UJF-6042 MkII Head Temp. Control

    We will shut ours off but as long as you maintain the shaking of the whites it will be fine. Even doing the white maintain option as well will be OK. This is also coming from a technician from pds.
  3. Mimaki CJV150 Print Head Problem - Anybody know what's going on?

    Check your environment make sure your temperature and humidity are correct. Also you change the dampers but before you did that did you purge the air out of them with the damper tool. Also do an overflow maintenance. And if needed a sub tank maintenance. Check your capping stations make sure...
  4. Mimaki UJF 3042 MKii - Calibrating

    We have the same machine. Work high look for anything that's infront of the laser beam on both sides. Any fuzz or partials on the jig and make sure your material is all level. LD Won't really do much depending on your downloaded profiles. Also check your laser return sensor. If dirty it will...
  5. Oce' 318 Flatbed Ink dropping out

    This is banding. Do nozzle wash and even a custody wash will help sometimes. Temp fixes you can up your passes and resolution. Print time is longer but it works. Also check your feed comp.
  6. UV Cleaning Solution

    I have a different uv machine but we use a basic flushing liquid or mimaki number 11 and 15. Some techs will use equal parts of water and isopropyl alcohol (70).
  7. Mimaki technician manual

    I have one. You can also join scribd and have almost anything you need at your fingertips. I have a ujf3042 and 4 ujf6042mkii that I run at work.
  8. T

    Having a water route error. Purged air from line pump looked like it was struggling but was...

    Having a water route error. Purged air from line pump looked like it was struggling but was working. Tubes weren't as warm but we had powered off for a bit. Anyone have the same thing before. I have ordered a pump and will replace that but was wondering what other issues could cause. Water...
  9. Anyone have a Mimaki UJF6042MK2 Service Manual to Share?

    Ever get a service manual?
  10. UJF-6042 Problem with Magenta draining

    Mine read 15. Was this your issue not enough positive pressure?
Top