• I want to thank all the members that have upgraded your accounts. I truly appreciate your support of the site monetarily. Supporting the site keeps this site up and running as a lot of work daily goes on behind the scenes. Click to Support Signs101 ...

Search results

  1. Possible pump issue

    Only white ink pump may cause this. Brushes are not meant to last 4ever, and white pump is used for recirculating. What errors you can find in message box? Or can you provide the error logs from tools tab?
  2. Question Oce Arizona 250gt Diy Head Replacement

    You are not in need of a dongle. Connect a usb keyboard, ctrl-alt-del, stop the software and regedit the values. You will find them in area "Oce Aries".
  3. Oce Arizona and Fuji Acuity Maintenance Station Purge setttings

    Engineering dongle But a question: where is your dongle from? you'd like to sell it? Or do you have access to service dongles? Expired ones maybe?
  4. Oce Arizona and Fuji Acuity Maintenance Station Purge setttings

    Head heght during purge Why the hell you raise the head on purging? Ink will spill everywhere around purge bucket... I keep the carriage in low purge position and clean the heads also in this position. There is space enpough. Have you found the setting for using expired ink longer then you are...
  5. SDS Key for Arizona 318GL -- Head change voltage

    Connect a Keyboard to USB, press Ctrl-Alt-Del and shutdown the Printer app. With mice go to Startmenu - Run and enter regedit. Then search for entry with serial, voltages and the AL-value and write it in. Restart Printer app located on Desktop and you are done.
  6. Ink Heat System Error - Oce 360XT

    Ink heat timeouts are normaly because of insufficent circulation of coolant fluid. Check pump and dampener in the right side of gantry. Or maybe one of the triac boards has blown. Heaters can be checked by Hand. There are a heater in the carriage and near the coolant pump.
  7. New Printer ??

    Printouts on a Latex 360 are not as sharp and detailed as on a solvent Roland or Mimaki. For outdoorit is very good, but for small Stickers it doesn't
  8. Static issue??? Help!!!! Pics...

    Use an airgun with ionized air, available in the web, and blow over the media. Use a grounding strap from Aluminium overlay to defined potential. Use a grounded brush with carbon fibres to eliminate surface static.
  9. Zund L3000 flatbed plotter user manual

    Wich series is it? G3 or G2?
  10. Changing a Printhead on Acuity Advance

    Remember to align printheads vertical (mechanical) and horizontal (Scanner-Alignment-Tool) If you don't have it let me know.
  11. 250 GT error messge

    Go to diagnostics Screen, then go to the tab utilities and generate the System logs. Access the shared Folder logs fom RIP-Station to gt the log files and put them on wetransfer and share the link here. I'm working since few years on arizona and can read and analyze. Will take a look onto and...
  12. SC-540 Printhead swap without changing ranking?

    If youre going changing the head rank the old ones are visible. Wright them down. They are for head voltage und puls Timing. You wont frie your Mainboard with wrong values, but for drop sizes and Timing alignment it is better to have the right values. Also you will find the head rank on sticker...
  13. SP300v blowing fuse f2 and transistor

    Blown F2 Try to startup machine with "repaired" Mainboard, but leave the cables from printhead disconnected. If the fuse is still blown, there is a Problem on the board. Also you can try to connect y-m PH to c-k connectors and check if PH has blown the board...
  14. Oce head alignment help needed...

    Head Alignment The thumb-screw is just for the vertical alignment. Horizontal must be made using the "scanner alignment tool" and Epson or Canon flatbed scanner. If with White you will Need it with backlight Option.