I want to thank all the members that have upgraded your accounts. I truly appreciate your support of the site monetarily. Supporting the site keeps this site up and running as a lot of work daily goes on behind the scenes.
Click to Support Signs101 ...
I had processes and excel spreadsheets to quote/price jobs but I've been doing this so long I just look at it for a minute or a day and barf out a number that seems too high. Then I mull it over for a minute or another day and make it higher.
Did you really just recommend calendared vinyl with calendared lam for a wall???
You will have shrinkage and glue lines, it will be a mess in 6 months. Use a wall product on walls...
Before changing any heads you need to check run the FORCE DROPLET DETECTION, this tells you how many heads are clogged.
Once you run it, write down the numbers for each head and then run a cleaning on all heads and run the test again. This will tell you what's really going on with your heads...
Or just don't worry about it...I've had my own shop since 1996, haven't lost one customer do to them dying or getting hurt in my shop. Insurance guys get paid to worry about everything, doesn't mean you have to.
I need two pieces of blank banner material 7' x 19'. They are to put in two gallery windows to act as curtains/blinds/blockout. They originally asked to put white static cling in the windows but i think just putting a blank blockout banner in the windows will be easier and more cost effective...
I run two HP 315s using the flexiprint that comes with them and you cannot run them on the same PC. I use two PCs, works well for an instant backup if one PC goes down. I backup each computer to the other. I have Flexipro installed on both, with the key in one of them. I never need the flexipro...
The font choice for the city and state is cringeworthy. Too bad there wasn't a few more lines of text, could have given you more chances on font selections....
I have run HP latex printers since 2011 and I would highly recommend latex. I currently have two HP 315 units, sometimes they run for days, sometimes they sit for weeks. They do not have issues with lengthy inactivity and are super reliable. I ran solvent machines before this and can say...