Problem is you need exact calibration. Need some time for to become perfect alignment.
1. table must be complete new alignment from all sides if you measure you find very big tolerances.
- table high sensor realignment is very urgent too.
2. Print gap for BIDI not more than 0.5
3. need to...
600$ for a brandnew head is not normal.....Normal Pricing is ~1.300-1.500,-€
i have some offers seen very cheaps like your pricing ~600$ but all cheat....you lost your money :notworthy:
Cleaning with ultrasonic will recover some deflection and clogged Nozzle.
But dont put the complete Head in fluid....only the Nozzleplate + 2mm (up to the screw plate dont deeper)
electronical insurance is a good choice !
electronical insurance is a good choice ! the other daily/weekly maintenace by your self.
Hold your machine always clean and it will be your workhorse :notworthy:
first...change the UV cable from left to right so you have controlled if this issue from cable.
Next step is the housing...there is temp controller inside this can be the troublemaker.
sorry nate but iam disagree with your simple statement.
in fakt is the camera is a very helpfull part for auto registration/adjustment bidi/head to head aligment and full autojetmapping... So you have on all media everytime the best quality. This is a feature for a real production machine.
In...
Nate.......has the CET Printers a Jetmapping Function ? Internal Camera System ? complete unattend clean & adjustment feature (AUTOTUNE) ? I read some Datasheets but nothing find about.
So you say "wins in every category" there is 2 100% different concept of machines :toasting:
Quality of...
3 thinks to check......
1st. Chip contacts often broken 1 nipple.
2nd ink pump/tubing
3rd subtank sensor
thats it !!!
But you need a ink cartridge that have a working chip !!!
New chip can be reset to zero from system if the subtank not filling in time !!!
Nothing more nothing less.
that...
Original HP inkcartridgesG0Y93A HP FB794 3-liter Cyan
Scitex Ink CartridgeG0Y94A HP FB794 3-liter Magenta
Scitex Ink CartridgeG0Y95A HP FB794 3-liter Yellow
Scitex Ink CartridgeG0Y96A HP FB794 3-liter Black
Scitex Ink CartridgeG0Y97A HP FB794 3-liter Light Cyan
Scitex Ink CartridgeG0Y98A HP...
yes i think the rod is worn...it is a bearing that works follow......left side rotating is to uncap/cap and right side rotating is working the inkpump..... if working to pump the bearing is free and left side rotating it will hold the rod an lift up aso....
Change the rod and all fine...
hmmm....i think if you have checked the chip reader board and this is ok is the next step to checkout the subtank(empty/full) contact...subtank is a silver back and on the side from subtankbag is a metalframe thats slide a sensor full or empty....
Whats going on with the subtank sensor...... is...